FLAMEX® EN 50382-2 FFS

Products

FLAMEX DTREN150056 EN 50382-2 1800V 120 FFS 120°C

Nexans ref. 10282209

  • Packaging: Drum (1000m)
  • Conductor cross-section: 120 mm²
  • Braid section: 11.6 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX DTREN150056 EN 50382-2 1800V 150 FFS 120°C

Nexans ref. 10282210

  • Packaging: Drum (1000m)
  • Conductor cross-section: 150 mm²
  • Braid section: 12.6 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX DTREN150056 EN 50382-2 1800V 185 FFS 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor cross-section: 185 mm²
  • Braid section: - mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX DTREN150056 EN 50382-2 1800V 240 FFS 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor cross-section: 240 mm²
  • Braid section: - mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX DTREN150056 EN 50382-2 1800V 25 FFS 120°C

Nexans ref. 13117415

  • Packaging: Drum (1000m)
  • Conductor cross-section: 25 mm²
  • Braid section: 6.3 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX DTREN150056 EN 50382-2 1800V 50 FFS 120°C

Nexans ref. 10275514

  • Packaging: Drum (1000m)
  • Conductor cross-section: 50 mm²
  • Braid section: 7.7 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX DTREN150056 EN 50382-2 1800V 70 FFS 120°C

Nexans ref. 13117416

  • Packaging: Drum (1000m)
  • Conductor cross-section: 70 mm²
  • Braid section: 8.9 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX DTREN150056 EN 50382-2 1800V 95 FFS 120°C

Nexans ref. 10263836

  • Packaging: Drum (1000m)
  • Conductor cross-section: 95 mm²
  • Braid section: 10.2 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX SI EN 50382-2 3600V 120 FFS 120°C

Nexans ref. 10260431

  • Packaging: Drum (1000m)
  • Conductor cross-section: 120 mm²
  • Braid section: 16.1 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 150 FFS 120°C

Nexans ref. 10260432

  • Packaging: Drum (1000m)
  • Conductor cross-section: 150 mm²
  • Braid section: 18.3 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 185 FFS 120°C

Nexans ref. 10260433

  • Packaging: Drum (1000m)
  • Conductor cross-section: 185 mm²
  • Braid section: 18.7 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 50 FFS 120°C

Nexans ref. 10235715

  • Packaging: Drum (1000m)
  • Conductor cross-section: 50 mm²
  • Braid section: 13.3 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 70 FFS 120°C

Nexans ref. 10260429

  • Packaging: Drum (1000m)
  • Conductor cross-section: 70 mm²
  • Braid section: 13.5 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 95 FFS 120°C

Nexans ref. 10260430

  • Packaging: Drum (1000m)
  • Conductor cross-section: 95 mm²
  • Braid section: 15.8 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

Description

Description

Standards

  • International
    EN 45545-2 (HL3); EN 50382-2; IEC 60228

FLAMEX® EN 50382-2 FFS shielded power cables are used for installations where enhanced electrical screening (EMC) is required. Able to withstand higher operating temperatures, these silicone-based cables allow to save cable weight.

DESIGN

1. Conductor
Flexible class 5 copper according to IEC 60228
    - tinned copper for 120°C Class
    - plain copper for 150°C Class

2. Insulation
Cross-linked silicone type EI 111 according to EN 50382-1
Separator: Unweaved tape

3. Screen
Tinned copper wire braid
Separator: Unweaved tape

4. Outer sheath
Cross-linked silicone type EM 107 according to EN 50382-1
Colour: black outer layer

Examples of marking: FLAMEX SI - EN 50382-2  - Voltage rate (1800V or 3600V) - cross-section mm² - FFS - temperature class (120°C or 150°C) - Manufacturing n° - NEXANS 279 - week/year
DTREN 150056 - EN 50382-2 - 1800V - cross-section mm² - FFS - temperature class (120°C) - Manufacturing N° - NEXANS 279 - week/year

 

FIRE SAFETY

FLAMEX® EN 50382-2 FFS shielded power cables are conform to EN 45545-2 HL3

 

GUIDE TO USE

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 10 x outer cable diameter
    • For installation and occasional movements: 12 x outer cable diameter
  • Pulling tensible force (dynamic) during installation: 50 N/mm² of copper size
  • Mechanical static tensible force: 15N/mm² of copper size

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tin plated copper
Conductor flexibility
Flexible class 5
Insulation
High temperature silicone
Screen
Tinned copper braid
Outer sheath
High temperature silicone
Halogen free
EN 60754-1 & EN 60684-2

Usage characteristics

Usage characteristics

Flame retardant
EN 60332-1-2
Fire retardant
IEC/EN 60332-3-24
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-50 ... 120 °C
Electro magnetic interference resistance
Yes
Max. conductor temperature in service
120 °C
Overload maximum core temperature
140 °C
Chemical resistance
Good

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close